Home | About Us | Our Expertise | Products & Services | Our Principle | Enquiry/Feedback | Contact Us

Products

punchline.jpg

TECHNICAL DATA

Tuned Harmonic Filter
Tuned-Harmonic-Filter.jpg
System Voltage : 400..660V
Filter Tuned to : 5th, 7th,11th, l3th
Rated KVar : 60....1800 KVar
Type : Auto/fixed Tuned Harmonic Filter. Harmonic filters consist of capacitors connected in series with reactor. The capacitors produce reactive power at the filter's fundamental frequency. A typical harmonic fiIter consists of three series resonant circuits tuned to the most common harmonics (5th, 7th & 11th harmonics). Harmonic filters are custom designed for each application using standard components. This ensures that the best possible power factor correction and filtering characteristics are achieved with a reasonable investment. This will help in reducing the total harmonic distortion in the system as per relevant standards like IEEES /9.

De - tuned Filter
De---tuned-Filter.jpg
System Voltage : 400....950V
Resonant Frequency : 141 Hz and 189 Hz, other frequencies on request and
3 rd order harmonic.
Rated KVar : De - tuned Filter 25....5000 KVar
Type : Auto / fixed
De - tuned fiIters are designed to be used for power factor correction in systems where harmonics are generated by nonlinear loads, each step of a de - tuned filters consists of a capacitor and low loss reactor connected in series. These two form a series resonant circuit tuned at a frequency below the lowest harmonic frequency present in the system normally the 5th (250Hz). De - tuned filter also removes lower order harmonics from the system to some extent. This helps to offset the resonance effect for longer trouble free operation.

LT Capacitor
LT-Capacitor.jpg
Rated voltage :
400V, 440 V, 480 V, 525 V, 610 V mains.
Tolerance :
2 times rated current continuous , 300 times rated current during short peaks.
Double Reliability : MPP
Self-healing at over
voltage peaks, over-pressure disconnector.
Lowest possible failure rate  :
200 ppm (parts per miIIion)

OSF (Active Filter)
OSF-Active-Filter.jpg
System Voltage : 400....660V
Compensating Current :
( r. m. s. ) : 60A, 90A,135A, 1 80A, 279A, 360A
Response time : < 40ms
Ambient Temperature:
0 to 400 C
The active filter is installed in parallel with the loads that generate the harmonics. It analyses the harmonic current generated by these nonlinear loads and the entire spectrum from the 2nd to the 25th harmonic or a specially targeted harmonic. This neutralizes the corresponding harmonic currents completely at the point of connection. This device consists of one filter for each phase so that even highly asymmetric harmonic pollution can be suppressed, as well as the 3rd, 9th and l5th harmonics, which add together arithmetically in the neutral conductor.

HT Capacitor & Associated Equipments

HT-Capacitor-Associated-E.jpg

Systems Voltage :
11 KV, 22 KV, 66KV
7.3  KV...onwards
Rated KVar :
50 KVar....10 MVar with series Reactor
High voltage power HT Capacitor Bank & capacitor units include wide range of equipments like RVTs, NDRs, GOD/DO Fuse, offload timer elevating hardware etc. The capacitors are dry or oil filled, one and three-phase all fiIm power and surge protection capacitors. Featuring the most modern technology, they are produced to meet the requirements of different climatic and operating conditions. They can be open or enclosed, high or low power, fixed power, integrated or for use with individual motors.

Thyristor Switched Capacitor Panels
Thyristor-Switched.jpg
System Voltage : 400....690V
Step Power : 50....300 KVar
Rated KVar : 50....1000KVar
Switching time : < 40ms.
Capacitor Panels with high-speed switching capability are designed to support the supply voltage of distribution systems comprising of welding machines and other fast switching loads to correct the power factor of connected loads. Thyristor switches are resistant to mechanical wear, operate without noise and are capable of practically transient-free switching. The minimum time taken by the control unit to switch on/off all the steps of the capacitor bank is a period of one cycle only.